新聞資訊
網站首頁 > 新聞資訊 >

DCS係統操作員職責是什麽?

2020-09-11 16:17:37 來源:http://www.qistar-garment.net/ 53

  操作員職責
  Operator responsibilities
  1、監視DCS係統運行,預防可能產生的危險。
  1. Monitor the operation of DCS system to prevent possible hazards.
  2、隨時幹預係統運行,確保安全、正常生產。
  2. Intervene system operation at any time to ensure safe and normal production.
  3、係統授權運行參數的更改。
  3. Change of system authorized operation parameters.
  4、自動控製投運方法:將畫麵中的回路儀表的手/自動開關打到自動即可。
  4. Automatic control operation method: set the manual / automatic switch of loop instrument in the picture to automatic.
  5、報警處理:工藝指標產生報警時會有聲音提示,報警信息在報警信息欄和報警一覽畫麵中指示,報警情況了解後,用消音按鈕關閉當前的報警聲音,並在報警一覽中確認。
  5. Alarm processing: when the process indicators give an alarm, there will be a sound prompt, and the alarm information will be indicated in the alarm information column and alarm list screen. After the alarm situation is known, the current alarm sound will be turned off with the mute button and confirmed in the alarm list.
  6、異常情況處理:
  6. Exception handling:
            浙大中控操作員軟件狗
  ▼自動控製過程中,出現變送器故障,應立即切回手動。
  In the process of automatic control, in case of transmitter failure, switch back to manual immediately.
  ▼如果出現閥門故障現象,此時應切回手動,改為現場操作。
  In case of valve failure, switch back to manual operation and change to field operation.
  ▼係統出現斷電,此時應立即切回手動,並要求工程師檢查係統情況,確認完好後方可再次投入自動。
  In case of power failure of the system, switch back to manual mode immediately and ask the engineer to check the system condition and put it into automatic mode again after confirming that it is in good condition.
  ▼DCS操作界麵數據不刷新(正常情況數據每秒刷新一次),手自動切換無法操作等情況,應聯係儀表人員進行維護。同時立即到現場操作。
  If the DCS operation interface data is not refreshed (the data is refreshed once per second under normal conditions), and the manual and automatic switching cannot be operated, the instrument personnel shall be contacted for maintenance. At the same time, they should go to the site immediately for operation.
  ▼出現係統卡件故障時應把相應控製回路切回手動,並由儀表人員更換故障卡件,檢查確認故障消除後方可再次投入自動。
  When the instrument circuit fails, the control personnel shall switch back to the control system to eliminate the fault.
  ▼DCS係統出現異常斷電,應改為手動操作。重新上電後,要求工程師檢查係統情況,檢查回路參數等係統數據是否正常,確認各調節閥的開度。一切正常後方可再次投入自動。
  The DCS system should be changed to manual operation in case of abnormal power failure. After power on again, the engineer is required to check the system condition, check whether the system data such as circuit parameters are normal, and confirm the opening of each control valve. After everything is normal, it can be put into automatic mode again.
  以上是關於DCS係統操作員職責的內容,相信大家都有所了解了,如想了解更多內容歡迎點擊浙大中控操作員軟件狗http://www.qistar-garment.net網站。